Culligan Deionized Water (High Quality Water Up to 18 megohms or < .05ppm)
TWO–BED The cation and anion exchangers are connected in series. The cation tank removes positively charged ions (calcium, sodium, magnesium, iron, manganese, potassium, etc). The anion tank removes negatively charged ions (sulfates, chlorides, carbonates, bicarbonates, nitrates, silica, etc). Strong base anion units typically produce 0.2 megohm water at a pH of 8-9, whereas weak base anion units produce lower water quality, a pH of 6-7, and do not remove silica or CO2.
MIXED–BED Cation and anion resins are combined and mixed in a single tank. Thousands of cation and anion ion exchanges take place as water passes through the resin bed. Typical water quality of 2 megohm or more with neutral pH.
MULTIPLE–TANK SYSTEMS Three tanks or more are connected in series; or parallel; or a combination of the two. Produces high purity water up to 18 megohm in any desired quantity. Systems may consist of strong acid cation, strong or weak base anion and mixed bed media tanks in a number of varying combinations, to produce the water quality required. Water qualities of 15 megohm or more, with a neutral pH, can typically be attained. |
|
Exchange Tank DI Service High Purity Water Systems · No capital investment · No labor costs · No maintenance costs · No chemicals Available as two-bed strong base, two-bed weak base, or mixed-bed systems. |
|
· Culligan Dealer Network - provides local expertise · Culligan Designed Regeneration Process - ensures consistent water quality · Exchange service also available for softening, carbon filtration & other special resins or media. |